Skip to content
AnutechSystems

Projects

A few we're allowed to talk about.

Most of our work sits behind NDAs. Below are six anonymized projects from the past five years that show the range of what our Fresno shop ships.

Almond processor · Madera County

PPO pasteurizer controls rewrite

Replaced a 12-year-old SLC 500 program with documented ControlLogix code, added validation reporting that cut audit-prep time from two days to two hours. Cutover completed during the off-season weekend shutdown.

98%
post-cutover uptime, season 1
18 hr
cutover window
3-day
FAT on the bench
PPO pasteurizer controls rewrite

Beverage co-packer · Fresno

Palletizing cell with auto-changeover

ABB IRB 660 cell integrated to existing case packer with pattern editor at the HMI. Operators run six SKUs without manual program changes. Payback inside one quarter on overtime savings alone.

6
SKU recipes
< 3 min
changeover
1 Q
ROI
Palletizing cell with auto-changeover

Municipal water district · Tulare County

Telemetered SCADA across 14 well sites

Ignition SCADA host with redundant servers, FreeWave radio telemetry to 14 well sites, Win-911 alarm dialing to an on-call rotation. AWWA-aligned cybersecurity baseline.

14
remote sites
99.9%
telemetry uptime
< 5 min
alarm dispatch
Telemetered SCADA across 14 well sites

Cold-storage operator · Visalia

MCC retrofit with VFDs on refrigeration fans

Replaced across-the-line starters with PowerFlex 525 VFDs on 24 condenser fans. Harmonic study, line reactors, kWh logger left in place to confirm savings.

24
fans converted
21%
kWh reduction
14 mo
payback
MCC retrofit with VFDs on refrigeration fans

Citrus packer · Kingsburg

Sorter + waxer + labeler line controls

Integrated a new sizer/grader with the existing waxer and a print-and-apply labeler, with line-speed sync and scrap routing. OEE dashboard published to supervisor desktops.

+12%
throughput
3
lines synced
1 yr
OEE tracking
Sorter + waxer + labeler line controls

Light manufacturer · Fresno

Energy submetering across 18 machines

Veris H8163 meters installed on each CNC and welder. Ignition historian, cost-per-part dashboard. Surfaced a single broken contactor pulling 30 A continuous.

18
machines metered
1
broken contactor caught
< 30 d
data live
Energy submetering across 18 machines
We can share a deeper case study under NDA. Ask Tyler.

Let's walk your plant

Tell us what you're trying to fix. We'll bring tools.

A free 45-minute site walk in Fresno, Clovis, Madera, Visalia and surrounding cities. You'll leave with a written scope, a budgetary number and a real timeline — not a sales deck.

Call now